Previous page     Contents     Next page

2.4 Experimental equipment

The following major equipment is now operational:

I. High-pressure apparatus
  • 1200 ton multi-anvil press (25 GPa, 3000°C)
  • 1000 ton multi-anvil press (25 GPa, 3000°C)
  • 3 piston-cylinders (0.5" and 0.75"; 4 GPa, 1800°C)
  • Cold-seal vessels (7 kbar, 750°C, gas & H2O), TZM vessels (3 kbar, 1100°C), rapid-quench equipment

  •  
    II. Structural analysis
  • 2 X-ray powder diffractometers
  • Single-crystal X-ray cameras
  • X-ray powder microdiffractometer
  • 2 automated single-crystal X-ray diffractometers
  • 2 Mössbauer spectrometers (1.5 - 1300 K)
  • Mössbauer millispectrometer
  • Variable-pressure-temperature Mössbauer spectrometer
  • FTIR spectrometer with IR microscope
  • 200 kV analytical FEG transmission electron microscope
  • 3 high-resolution solid-state NMR spectrometers (100, 200, 300 MHz)
  • Raman spectrometer

  •  
    III. Chemical analysis
  • Cameca SX-50 electron microprobe; fully-automated with 10-crystal, 4 spectrometer configuration, BSE detector and capability for light elements
  • ICP analysis system
  • Determination of water content by Karl-Fischer titration

  •  
    IV. In-situ determination of properties
  • 2 calorimeters (77 - 1000 K scanning; 700 - 2200 K drop and scanning)
  • 2 dilatometers (to 1500°C; viscosity by penetration, parallel-plate, fibre elongation and beam-bending; thermal expansivity measurements)
  • Diamond anvil cells for single crystal X-ray diffraction, Mössbauer spectroscopy Raman scattering, infrared and optical spectroscopy and hydrothermal studies
  • 1-atm furnaces (to 2100°C, gas mixing) including apparatus for viscometry, densitometry and galvanic thermo-chemistry, centrifuge studies
  • Rotation viscometer
  • Solid medium Griggs-Blacic deformation apparatus
  • 1-atm high-temperature creep apparatus
  • Splat quencher
  • Fragmentation bomb and chamber for studies of explosive volcanism
  • 2 high frequency ultrasonic interferometers (crystalline and molten materials)
  • Gigahertz ultrasonic interferometer and an interface adaptor to resistance-heated diamond-anvil cells
  • Heating stage for fluid inclusion studies
  • Impedance/gain-phase analyzer for electrical conductivity studies
  • Internally heated autoclave for centrifuge studies
  • The Geoinstitut has access to an analytical scanning electron microscope and to the university computer centre.

    The Institute is provided with well equipped machine shops, electronic workshop and sample preparation laboratory. The institute has access to CYBER and VAX 8600 computers in the computer center of the university.

    A third multianvil press (5000 t) and an internally heated autoclave (10 kbars, ca. 1500°C) have been ordered and should become operational during 1997.

    Bayerisches Geoinstitut, Universität Bayreuth, 95440 Bayreuth, Deutschland
    Tel: +49-(0) 921 55 3700 / 3766, Fax: +49-(0) 921 55 3769, E-mail: bayerisches.geoinstitut(at)uni-bayreuth.de